ZKS-250AE
250W AT switching power supply
|
|
|
|
 |
|
Input Voltage: |
90~135VAC, nominal 115VAC (90V at 200W, 103V at 250W load) or 180~265VAC, nominal 230VAC; selectable by side switch |
 |
Input Frequency: |
47~63Hz single phase |
 |
Input Current: |
6A (RMS) for 115VAC at without AC outlet; 3A (RMS) for 230VAC |
 |
Inrush Current: |
70A at cold start |
 |
Switching Frequency: |
30KHz typical |
 |
Hold Up Time: |
16ms min. |
 |
Brown Out Voltage: |
95V~max. 60Hz |
 |
Output Power: |
250W at 45°C |
 |
Power Up Time: |
< 20ms for +5V output voltage |
 |
Power Good: |
The power good signal will not be higher than 100~500ms after the +5V output stabilizes at its operating value when the unit is turn on |
 |
Power Fail: |
The TTL compatible signal will go down at least 1ms before +5V below 4.75V |
 |
Efficiency: |
80% min. at full load (AC input 230V) |
 |
Altitude: |
10,000 feet |
 |
Protection |
Over Voltage: 5.5~6.9V for +5V output, 13.8~15.6V for +12V output
Over Load: Total output from 110% min. to 140% max.; all output equipped w/short circuit protection; the outputs shall shut down if shorted to zero volts output |
 |
Thermal System: |
Forced air ventilation by DC ball bearing cooling fan; fan status monitoring is optional |
 |
Temperature Coefficient: |
+0.05% per°C |
 |
Temperature: |
Operating: 0~50°C Storage: -10~+70°C |
 |
Humidity: |
Operating: 20~90% RH Storage: 10~98% RH |
 |
Dimensions: |
15.0 x 14.0 x 8.6 cm |
|
|
|
|
|
 |
|
Safety: |
UL 1950, E147701; TUV EN60950, R9552086 (Rheinland); NORDIC (N, D, S, FI); CE Report, ET84S-04-026 (ETC) |
|
|
|
|
|
| NOTE: A low pass filter shall be added to outputs during measurement. (exp: 0.47uF Tan-cap. + 0.1uF Ceramic-cap.) |
|
|
+V1 |
+V2 |
-V3 |
-V4 |
 |
|
DC Output |
+5V |
+12V |
-5V |
-12V |
|
Max. Current |
25A |
10A |
0.5A |
0.5A |
|
Min. Current |
2.5A |
0.4A |
0A |
0A |
|
Load Regulation |
5% |
5% |
10% |
10% |
|
Line Regulation |
1% |
1% |
2% |
2% |
|
Ripple & Noise |
50mV |
100mV |
150mV |
150mV |
|
|
|
|