公司簡介 ISO認證 環境政策 與我們連絡
Investor Relation Coperate Governance
單板電腦 液晶平板電腦 準系統 機箱 無源底板 電源供應器 擴充附加卡 週邊設備
FCC/CE證書 使用手冊 驅動程式 BIOS更新
庫存零件拍賣




MPM-9561
60W Open Frame Power Supply

Datasheet

Specifications
Input Voltage:
85~264VAC
Input Frequency:
47~63Hz at AC input
Input Current:
2A at 115VAC or 1.5A at 230VAC max.
Inrush Current:
The maximum inrush current will not exceed 30A at 115VAC or 60A at 230VAC input, cold start, 25°C
Load Range:
The adjustable range of +5V output is around 4.5~5.8V. At factory, the +5V output is set to between 4.95~5.05V at 60% rated load, and +/-12V are checked to be within the specified voltage accuracy range. The peak load cannot exceed 5 sec.
Ripple and Noise:
The peak to peak ripple and noise for +5V output is less 50mV for +/-12V output are less than 100 mV. Measuring is done by 15MHz bandwidth limited oscilloscope and terminated each output with a 0.47μF capacitor
Line Regulation:
The line regulation for each output is less than +/-1% while measuring at rated load and +/-10% of the input changing
Load Regulation:
The load regulation for +5V is less than +/-1%, for +/-12V is less than +/-5%, measured is done by changing the measured output load +/-40% from 60% rated load, and keep all other output at 60% rated load
Hold Up Time:
The hold up time is longer than 16mS at 115VAC input and rated load, which is measured from the end of the last charging pulse to when the main output drops down to 95%output voltage
Efficiency:
The efficiency is higher than 75% typical while measuring at nominal line and rated load
Protection:
For some reasons the power supply fails to control itself, the build-in over voltage protection circuit will shut down the outputs to prevent damaging to external circuits. The trip point of crowbar circuit is around 5.8V to 7V for output voltage. The power supply will go into latch off mode against short circuit or over load conditions
Dimensions:
7.62 x 12.7 x 3.87 cm

Safety Standards
Safety:
UL 544 & UL 2601-1 / CSA 22.2 No. 601-1 / TUV (DIN. VDE 0750T. 1/12.91/ EN 60601-1: 1990)
GND Leakage Current:
It should be less 100μA at 244VAC input
EMS:
IEC-801-2 8KV air discharge criteria B / IEC-801-3 3V/M / IEC-801-4 0.5KV
EMI:
FCC docket 20780 curve "B" / EN 55011 "B" / EN61000-3-2

Output Voltage
Min. Load
Rated Load
Peak Load
Voltage Accuracy
+5V
0A
5A
8A
4.95~5.05V
+12V
0A
2.3A
3.5A
11.4~12.6V
-12V
0A
0.5A
----
-11.4~-12.6V