Input Voltage: |
85~270VAC |
 |
Input Current: |
2A at 115VAC or 1A at 230VAC max. |
 |
Inrush Current: |
Not exceed 30A at 115VAC input or 60A at 230VAC input, at cold start 25°C, and excluding EMI suppression capactiors |
 |
Load Range: |
All outputs are at min. load conditions, while +5V output is between 5~5.1V and all other outputs are within the specified voltage accuracy range |
 |
Ripple And Noise: |
Peak to peak ripple and noise for all outputs is < 1% of output voltage at rated load |
 |
Line Regulation: |
< +/-2% for each output measured at rated load and +/-10% input voltage range |
 |
Load Regulation: |
< +/-3% for +5V, +/-4% for +12V, and +/-5% for -12V with +/-40% change on the measured output load, +/-40% from 60% rated load, while keeping other outputs at 60% rated load |
 |
Hold Up Time: |
> 16ms at 115VAC input and rated load, measured from the end of the last charging pulse to when the main output drops down to 95% output voltage |
 |
Efficiency: |
> 70% at nominal line and rated load |
 |
Altitude: |
10,000 feet |
 |
Protection |
Latch-off mode against short circuit or over load conditions AC input ON/OFF cycle to restart power supply |
 |
Temperature: |
Operating: 0~50°C Storage: -40~+85°C |
 |
Connectors: |
AC Input: Molex 5277-02A or equivalent device
DC Output: Molex 5273-08A or equivalent device
For Fan Use Only: Molex 5045-02A or equivalent device |
 |
Dimensions: |
12.7 x 7.62 x 3.86 cm at tolerance +/-0.4mm |
|
|