Input Voltage: |
90~130VAC or 180~260VAC |
 |
Input Frequency: |
47~63Hz |
 |
Inrush Current: |
Not exceed 30A at 115VAC input or 60A AC input, at cold start 25°C |
 |
Load Range: |
When all outputs are in 60% rated load condition, the +5V output is set between 4.98~5.02V while all other outputs are within the specified voltage accuracy range |
 |
Ripple And Noise: |
Peak to peak ripple and noise for +5V, output is < 50mV, and < 100mV for +12V, -12V, -5V outputs at rated load, 115/230VAC |
 |
Line Regulation: |
< +/-1% for each output at rated load and +/-10% of 115VAC or 230VAC input voltage change |
 |
Load Regulation: |
The output voltage load regulation is less than the value on the table when subjected to +/-40% change on each output load from 60% rated load, and while all other outputs are at 60% rated load |
 |
Hold Up Time: |
> 16ms at 115VAC input and rated load measured from the last AC line charging pulse to the point when +5V drops to +4.75V |
 |
Output Power: |
The total DC continuous power is whthin 230W at < 30°C ambient temperature |
 |
Power Good: |
When turned on, the signal goes high 100~500ms after all output DC voltages are within regulation limits |
 |
Power Redundancy: |
This power supply has power redundant capability |
 |
Efficiency: |
> 70% at rated load |
 |
Altitude: |
10,000 feet |
 |
Protection |
Built-in over voltage protection circuit shuts down the outputs to prevent damage. Trip point of crowbar circuit is between 5.7~7V; latch off mode against short circuit or over load conditions AC line ON/OFF cycle recovers unit from fault conditions |
 |
Temperature: |
Operating: 0~40°C Storage: -40~+75°C |
 |
Humidity: |
Operating: 5~95%; non-condensing at 40°C |
 |
Connectors: |
AC: One AC input socket DC: O1 DIN 41612 C96 |
 |
Dimensions: |
14.0 x 15.0 x 8.62 cm +/-5mm tolerance |
 |
MTBF: |
235,743 hrs. |
|
|