Input Voltage: |
85~264VAC |
 |
Input Frequency: |
47~63Hz |
 |
Input Current: |
3A at 115VAC or 1.5A at 230VAC max. |
 |
Inrush Current: |
< 30A at 115VAC input or < 60A at 230VAC input at 25°C cold start |
 |
Load Range: |
With the +5V output set between 5.08~5.13V and all output at 60% raged load, while the other outputs are withing the accuracy range; max. total combined output power on the 3.3V and 5V rails is 70W, with the max. load not exceeding 120W |
 |
Ripple And Noise: |
Peak to peak ripple and noise is < 50mV for +5V and 3.3V outputs, 120mV for +5Vsb, < 120mV for +12V, and 200mV for -12V at rated load and nominal input |
 |
Line Regulation: |
< +/-1% for rated load with a +/-10% change in input voltage |
 |
Load Regulation: |
< +/-2% for +5V, < +7~-3% for +12V, < +8~-3% for -12V, < +/-5% for +3.3V with measured output load changing within +/-40% and 60% rated load, while keeping other outputs at 60% rated load |
 |
Hold Up Time: |
> 16ms at 115VAC input and rated load |
 |
Power ON/OFF: |
Turns on power supply when power on/off pin is connected to secondary GND |
 |
Efficiency: |
> 70% at nominal line and rated load |
 |
Altitude: |
10,000 feet |
 |
Protection |
Hiccup mode against short circuit or over load conditions auto recovery when fault conditions are removed |
 |
Temperature: |
Operating: 0~50°C; output power is 100W with 6CFM forced air, 120W with 18CFM forced air Storage: -40~+85°C |
 |
Connectors: |
AC Input: Molex 5273-05A withdraw 2-pin or equivalent device
DC Output: TB2 is Molex 5273-14A or equivalent device; TB3 is Molex 5045-03A or equivalent device |
 |
Dimensions: |
8.38 x 15.24 x 3.97 cm. Tolerance at +/-0.4mm |
|
|