Input Voltage: |
The range of input voltage is from 10~30VDC, nominal input voltage is 12 and 24VDC |
 |
Input Current: |
18A at 10VDC max. |
 |
Inrush Current: |
Less than 30A at 10VDC input |
 |
Load Range: |
At the factory, the +5V output is set between 5.08~5.13V and all output at 60% rated load; the other outputs are checked to be within the accuracy range. The maximum total combined output power on the +3.3V and +5V rails is 70W. The max. load cannot exceed 120W |
 |
Ripple And Noise: |
The peak to peak ripple and noise for +5V, +3.3V output are less than 100mV for +5V sb is 120mV, for +12V is less than 120mV, for -12V is less than 200mV at ranted load and nominal input, with is measured by a 20MHz bandwidth limited oscilloscope and the each output is connected with a 0.47uF capacitor |
 |
Line Regulation: |
Less than +/-2.5% at rated load with +/-10% change in input voltage |
 |
Load Regulation: |
+5V is less than +/-2%, for +12V is less than +/-5%, for -12V +/-5%, +3.3V is less than +/-5% while the measuring is done by changing the measured output loading +/-40% from 60% rated load, and keep other output is at 60% rated load |
 |
Efficiency: |
> 70% while measuring at nominal line and rated load |
 |
Altitude: |
0~10,000 feet |
 |
Protection |
The power supply will generate the hiccup mode to protect itself against short circuit or over load condition, and will return to normal after wrong condition is removed |
 |
Power On/Off: |
The power supply will start-up when the power on/off pin be connected to secondary GND |
 |
Power Good Signal: |
The power is turned on, the power good signal will go high between 100ms to 500ms after all output DC voltage are within regulation limits |
 |
Power Fail Signal: |
The power fail signal will go low at least 1ms before any of the output voltages fall below the regulation limits |
 |
Temperature: |
Operating: 0~50°C, output power is 120W forced air cooling, 85W convection cooling Storage: -20~+70°C |
 |
Humidity: |
10~90%, non-condensing |
 |
Connectors: |
DC Input (CN1): Dinkle DT-35-B01W-03 or equivalent
DC Output (CN2): Molex 5273-14A or equivalent
DC Output (CN3): Molex 5045-03A or equivalent
Power Good Output (CN4): Molex 5045-02A or equivalent
Fan Output (CN5): Molex 5045-02A or equivalent |
 |
Dimensions: |
15.24 x 8.38 x 3.8 cm with +/-0.4mm tolerance |
|
|