Input Voltage: |
10~30VDC with normal line at +24VDC |
 |
Input Frequency: |
47~63Hz |
 |
Input Current: |
13A at 10VDC max. |
 |
Inrush Current: |
< 15A at 10VDC input from cold start excluding EMI capactiors |
 |
Load Range: |
With all other outputs within their specified voltage accuracy ranges and 60% rated load conditions, the +5V output is between 5~5.1V. It could last 10 sec. at peak load and 25°C |
 |
Ripple And Noise: |
Peak to peak ripple and noise for +5V is < 50mV, and < 100mV for the other |
 |
Line Regulation: |
< +/-2% for each output at rated load and < +/-10% +12V and +24V input variables |
 |
Load Regulation: |
< +/-1% for +5V, < +/-5% for +12V and -12V |
 |
Efficiency: |
> 70% at nominal line and rated load |
 |
Altitude: |
10,000 feet |
 |
Protection |
Built-in over voltage protection circuit. Trip point of crowbar circuit is between 5.7~7V hiccup mode against short circuit or over load conditions auto recovery when fault conditions are removed O.C.P. of +5V is 20A max. |
 |
Temperature: |
Operating: 0~50°C Storage: -40~+85°C |
 |
Connectors: |
DC Input: Terminal blocks
DC Output: Molex 5273-04A or equivalent device
For Fan Use Only: Molex 5045-02A or equivalent device |
 |
Dimensions: |
12.7 x 7.62 x 3.86 cm at tolerance +/-0.4mm |
|
|