Input Voltage: |
85~264VAC |
 |
Input Frequency: |
47~63Hz |
 |
Input Current: |
3A at 115VAC or 1.5A at 230VAC |
 |
Inrush Current: |
< 30A at 115VAC input or < 60A at 230VAC input, under 24°C cold start |
 |
Load Range: |
With all output at 60% rated load, +5V is between 4.95V and 5.05V. All other outputs are within the accuracy range. Effective so long as the max. load does not exceed 90W continuous convection cooling |
 |
Ripple And Noise: |
Peak to peak ripple and noise for each output is < 1% of each output's voltage at rated load |
 |
Line Regulation: |
< +/-1% for rated load with +/-10% change in input voltage |
 |
Load Regulation: |
< +/-1% for +5V and < +/-5% for all other outputs |
 |
Hold Up Time: |
> 16ms at 115VAC input and rated load |
 |
Efficiency: |
> 70% measured at nominal line and rated load |
 |
Altitude: |
10,000 feet |
 |
Protection |
Built-in crowbar circuit. Trip point is between 5.7~7V. AC line off and on cycle for over voltage recovery and restart hiccup mode protection against short circuit or over load condition |
 |
Temperature: |
Operating: 0~50°C forced air 30CFM needed when output > 80W Storage: -40~+85°C |
 |
Connectors: |
AC Input: Molex 5273-05A withdraw 2-pin or equivalent device
DC Output: Molex 5273-12A or equivalent device |
 |
Dimensions: |
7.0 x 20.0 x 3.8 cm at tolerance +/-0.4mm |
|
|