Input Voltage:
90~135VAC, nominal 115VAC (90V at 200W, 103V at 250W load or 180~265VAC, nominal 230VAC; selectable by side swith) |
Input Frequency:
47~63Hz single phase |
Input Current:
6A (RMS) at 115VAC at without AC outlet; 3A (RMS) for 230VAC |
Inrush Current:
70A at cold start |
Switching Frequency:
30KHz typical |
Hold Up Time:
16ms min. |
Brown Out Voltage:
95V~max. 60Hz |
Output Power:
250W at 45°C |
Power Up Time:
< 20ms for +5V output voltage |
Power Good Signal:
The power good signal will not be higher than 100~500ms after the +5V output stabilizes at its operating value when the unit is turned on |
Power Failure:
The TTL compatible signal will go down at least 1ms before +5V below 4.75V |
Efficiency:
80% min. at full load (AC input 230V) |
Altitude:
10,000ft |
Protection:
Over Voltage: 5.5~6.9V for +5V output, 13.8~15.6V for +12V output Over Load: Total output from 110% min. to 140% max.; all output equipped w/short circuit protection; the outputs shall shut down if shorted to zero volts output |
Thermal System:
Forced air ventilation by DC ball bearing cooling fan; fan status monitoring is optional |
Temperature Coefficient:
+0.05% per °C |
Temperature:
0~+50°C (operating); -10~+70°C (storage) |
Humidity:
20~90% RH (operating); 10~98% RH (storage) |
Safety:
UL 1950 E147701 / TUV EN60950, R9552086 (Rheinland) / NORDIC (N, D, S, FI) / CE Report, ET84S-04-026 (ETC) |
Dimensions: