Input Voltage:
The range of input voltage is from 30~120VDC, nominal input voltage is 48 and 90VDC |
Input Current:
The maximum is 7A at 30VDC input |
Inrush Current:
The inrush current is less than 70A at 30VDC input |
Load Range:
At the factory, the +5V output is set between 5.08V to 5.13V and all output at 60% rated load; the other outputs are checked to be within the accuracy range. The maximum total combined output power on the +3.3V and +5V rails is 70W. The max. load connot exceed 120W |
Ripple And Noise:
The peak to peak ripple and noise for +5V, +3.3V output are less than 100mV for +5Vsb is 120mV, for +12V is less than 120mV, for -12V is less than 200mV at ranted load and nominal input, which is measured by a 20MHz bandwidth limited oscilloscope and the each output is connected with a 0.47uF capacitor |
Line Regulation:
The line regulation is less than +/-2.5% at rated load with +/-10% change in input voltage |
Load Regulation:
The load regulation for +5V is less than +/-2%, for +12V is less than +/-5%, for -12V +/-5%, +3.3V is less than +/-5% while the measuring is done by changing the measured output loading +/-40% from 60% rated load, and keep other output is at 60% rated load |
Power On/Off:
The power supply will start-up when the power On/Off pin be connected to secondary GND |
Power Good Signal:
The power is turned on, the power good signal will go high between 100ms to 500ms after all output DC voltage are within regulation limits |
Power Fail Signal:
The power fail signal will go low at least 1ms before any of the output voltages fall below the regulation limits |
Efficiency:
The efficency is higher than 70% while measuring at nominal line and rated load |
Altitude:
0~10,000ft |
Protection:
The power supply will generate the hiccup mode to protect itself against short circuit or over load condition, and will return to normal after wrong condition is removed |
Temperature:
0~+50°C, outpur power is 120W forced air cooling, 85W convection cooling (operating); -20~+70°C (storage) |
Humidity:
10~90%; non-condensing |
Connectors:
DC Input: Dinkle DT-35-B01W-03 or equivalent DC Output: Molex 5273-14A or equivalent DC Output: Molex 5045-03A or equivalent Power Good Output: Molex 5045-02A or equivalent Fan Output: Molex 5045-02A or equivalent |
Safety:
UL 60950 / CSA 22.2 No.234 / EN60950 |
EMI:
FCC docket 20780 curve B / EN55022B |
EMS:
IEC-801-2 Level 3 / IEC-801-3 Level 3 / IEC-801-4 Level 4 |
Dimensions:
8.38 x 15.24 x 3.81 cm; tolerance specified is +/-0.4mm |
|