Input Voltage:
90~132VAC or 180~260VAC |
Input Frequency:
47~63Hz |
Input Current:
Does not exceed 30A at 115VAC input or 60A AC input, at cold start 25°C |
Load Range:
When all outputs are in 60% rated load condition, the +5V output is set between 4.98~5.02V while all other outputs are within the specified voltage accuracy range |
Ripple And Noise:
Peak to peak ripple and noise for +5V, outputs is < 50mV, and < 100mV for +12V, -12V, -5V outputs at rated load, 115/230 VAC |
Line Regulation:
< +/-1% for each output at rated load and +/-10% of 115VAC or 230VAC input voltage change |
Load regulation:
The output voltage load regulaton is less than the value on the table when subjected to +/-40% change on each output load from 60% rated load, and while all other outputs are at 60% rated load |
Hold Up Time:
> 16ms at 115VAC input and rated load measured from the last AC line charging pulse to the point when +5V drops to +4.75V |
Output Power:
The total DC continuous power is within 230W at < 30°C ambient temperature |
Power Good Signal:
When turned on, the signal goes high 100~500ms after all output DC voltages are within regulaton limits |
Power Redundancy:
This power supply has power redundant capability |
Efficiency:
> 70% at rated load |
Altitude:
10,000 feet |
Protection:
Built-in over ovltage protection circuit shuts down the outputs to prevent damage. Trip point of crowbar circuit is between 5.7~7V; latch off mode against short circuit or over load conditions AC lone NO/OFF cycle recovers unit from fault conditions |
Temperature:
0~+40°C (operating); -40~+75°C (storage) |
Humidity:
5~95%; non-condensing at 40°C (operating) |
Connectors:
AC: One AC input socket DC: 01 DIN 41612 C96 |
Safety:
UL 1950 / CSA 22.2 No.234 / VDE EN60950 |
EMI:
FCC class B / EN55022 B |
EMS:
Level 3 of IEC-801, 802, 803, 804 |
Dimensions:
14.0 x 15.0 x 8.62 cm +/-5mm toterance |
MTBF:
235,743 hrs. |
|